Dental zirconia sintering furnaces are a special case: a small chamber, a high and tightly controlled temperature, and a need for clean, repeatable heat. Here is how to spec the element.

Our dental zirconia sintering guide gives the temperature and grade detail.

What a dental furnace needs

Requirement Recommended element spec
Sintering temperature ~1500–1550°C hold → EQ1800 MoSi2
Chamber size Compact → Φ4/9 U-type
Atmosphere Air / oxidising (standard)
Heat-up Fast, low thermal mass
Mounting Single-ended U, one-wall penetration

Spec checklist

  1. Grade: EQ1800 for the 1500–1550°C zirconia hold (gives margin over EQ1700).
  2. Diameter: Φ4/9 fits most bench-top dental units (e.g. Sirona HTC Infire); verify against your drawing.
  3. Quantity & layout: match the original element count and U-bend reach.
  4. Shank spacing: match your furnace wall thickness and terminal layout.

See our diameter guide and temperature grades for the supporting numbers.


About the author: This guide was prepared by the HeatingDriver technical team — heating-element engineers with nearly 20 years of experience supplying MoSi2 and SiC elements to dental, ceramics and research labs worldwide. Need a sizing check? Browse our MoSi2 elements or send us your furnace drawing.

Related guides

Why Specify Molybdenum Disilicide (MoSi2) heating elements with HeatingDriver

HeatingDriver is a manufacturer and exporter of Molybdenum Disilicide (MoSi2) heating elements with nearly 20 years of experience supplying furnace builders, labs, and integrators worldwide. We stock standard grades and build custom sizes from your drawings, and we review your element drawings free of charge before production. Browse our Molybdenum Disilicide (MoSi2) heating elements catalog or contact our engineers for a quote.

Frequently Asked Questions

Q: Which MoSi2 grade suits a dental zirconia sintering furnace?

EQ1800 for the roughly 1500–1550°C zirconia hold. It gives useful margin over EQ1700 at that sustained sintering temperature.

Q: Which element diameter fits a bench-top dental unit?

Φ4/9 U-type fits most bench-top dental furnaces, for example the Sirona HTC Infire, but always verify the size against your own furnace drawing before ordering.

Q: What besides grade and diameter has to match the original?

Match the element count and U-bend reach for the layout, and match shank spacing to your furnace wall thickness and terminal arrangement. Dental furnaces normally use single-ended U elements with one-wall penetration.

Q: Why is MoSi2 well suited to dental sintering?

A dental furnace has a small chamber, a high and tightly controlled temperature, and a need for clean, repeatable heat. MoSi2 delivers fast heat-up with low thermal mass in a standard air or oxidising atmosphere, which fits that duty.